VIII. Sensors Commands

To monitor the operational environment of a SpinServer system, use the sensors commands to display fan and temperature information. The sensors command node includes the following subnode commands:

  • fan

  • power

  • temp

  • ups

Each of the subnode commands and its leaf-node commands is described in detail, with parameters and arguments listed for each command.

All of the subnodes include the show leaf-node command.

Examples of command usage are included in the discussions.

Table of Contents
sensors fan show — Use the sensors fan show command to view operational information for the intake, exhaust, and CPU fans in a SpinServer cluster.
sensors power show — Use the sensors power show command to view power information for a SpinServer's motherboard and CPU.
sensors temp show — Use the sensors temp show command to view operating temperature information for a SpinServer's motherboard and CPU.
sensors ups show — Use the sensors ups show command to view operational information for a SpinServer's uninterruptible power supply (UPS).

sensors fan show

Name

sensors fan show -- Use the sensors fan show command to view operational information for the intake, exhaust, and CPU fans in a SpinServer cluster.

Synopsis

CLI:

sensors fan show [-ssid spinserver -key fan_ID]

GUI: Navigate to the Sensors → Fans node. To display information about a specific fan, select it from the table and run the Show command from the drop-down menu of the action pane.

Description

The sensors fan show command displays information about the operational performance of the intake, exhaust, and CPU fans in a SpinServer cluster. The fan speed is given in RPMs. Use the command with the -ssid and -key parameters to display detailed information about one fan, or with no parameters to display information about all of the fans in a SpinServer.

Options

[-ssid spinserver]

This is the ID given to the SpinServer. This parameter is optional; however, if it is used, the -key parameter must also be specified.

[-key fan_ID]

This is the ID of a specific fan in the SpinServer. This parameter is optional; however, if it is used, the -ssid parameter must also be specified.

Example

The following command example displays information about the operational performance of the intake, exhaust, and CPU fans in a SpinServer cluster.

spinserver::> sensors fan show 
Host Name Fan ID    Fan Description    Speed (RPM)
                                                  
sserv10   7-5    Chassis Intake Fan 3   2,250      
sserv10   7-6    Chassis Intake Fan 4   2,250      
sserv10   7-4    Chassis Intake Fan 2   2,250      
sserv10   7-7    CPU 1 Fan              5,037      
sserv10   7-3    Chassis Intake Fan 1   2,250      
sserv10   7-8    CPU 2 Fan              5,037      
sserv10   7-2    Chassis Exhaust Fan 2  0          
sserv10   7-1    Chassis Exhaust Fan 1  2,860      
sserv9    7-1    Chassis Exhaust Fan 1  2,860      
sserv9    7-6    Chassis Intake Fan 4   2,109      
sserv9    7-5    Chassis Intake Fan 3   2,250      
sserv9    7-8    CPU 2 Fan              4,963      
sserv9    7-2    Chassis Exhaust Fan 2  0          
sserv9    7-7    CPU 1 Fan              5,000      
sserv9    7-4    Chassis Intake Fan 2   2,250      
sserv9    7-3    Chassis Intake Fan 1   2,250 

The following command example displays information about the operational performance of the fan named 7-5 in a SpinServer named serv10.

spinserver::> sensors fan show -ssid serv10 -key 7-5
Host Name         sserv10                                 
Fan ID            7-5                                     
Fan Description   Chassis Intake Fan 3                     
Speed (RPM)       2,250                                   

sensors power show

Name

sensors power show -- Use the sensors power show command to view power information for a SpinServer's motherboard and CPU.

Synopsis

CLI:

sensors power show [-ssid spinserver -key sensor_ID]

GUI: Navigate to the Sensors → Power node. To display information about a specific power sensor, select it from the table and run the Show command from the drop-down menu of the action pane.

Description

The sensors power show command displays information gathered from a SpinServer's power sensors. Use the command with the -ssid and -key parameters to display detailed information about one power sensor, or with no parameters to display information about all of the power sensors in a SpinServer. The command displays the following information:

Options

[-ssid spinserver]

This is the ID given to the SpinServer. This parameter is optional; however, if it is used, the -key parameter must also be specified.

[-key sensor_ID]

This is the ID of the specific power sensor in the SpinServer. This parameter is optional; however, if it is used, the -ssid parameter must also be specified.

Example

The following command example displays warnings and information about the power of the motherboards and CPUs in a SpinServer cluster.

spinserver::> sensors power show 
Host Name Sensor ID     Sensor Description            Voltage

Server1   33         3.3 Volt Supply           3.3712
Server1   12         12.0 Volt Supply          12.1875
Server1   CPU        CPU Core Voltage          1.4382
Server1   50         5.0 Volt Supply           5.044
Server2   33         3.3 Volt Supply           3.3712
Server2   50         5.0 Volt Supply           5.018
Server2   12         12.0 Volt Supply          12.1875

sensors temp show

Name

sensors temp show -- Use the sensors temp show command to view operating temperature information for a SpinServer's motherboard and CPU.

Synopsis

CLI:

sensors temp show [-ssid spinserver -key sensor_ID]

GUI: Navigate to the Sensors → Temperature node. To display information about a specific temperature sensor, select it from the table and run the Show command from the drop-down menu of the action pane.

Description

The sensors temp show command displays operating temperature information about the motherboard and CPU in a SpinServer enclosure. The temperatures are listed in Celsius degrees. Use the command with the -ssid and -key parameters to display information about one temperature sensor, or with no parameters to display information about all of the temperature sensors in a SpinServer.

Options

[-ssid spinserver]

This is the ID given to the SpinServer. This parameter is optional; however, if it is used, the -key parameter must also be specified.

[-key fan_ID]

This is the ID of the specific temperature sensor in the SpinServer. This parameter is optional; however, if it is used, the -ssid parameter must also be specified.

Example

The following command example displays warnings and information about the operating temperature of the motherboard and CPU in a SpinServer enclosure.

spinserver::> sensors temp show 
Host Name Sensor ID     Sensor Description     Temperature (Celsius)
                                                                    
sserv10   7-10       CPU 1 Temperature         38                   
sserv10   7-11       Motherboard Temperature 2 40                   
sserv10   7-12       CPU 2 Temperature         41                   
sserv10   7-9        Motherboard Temperature 1 42                   
sserv9    7-10       CPU 1 Temperature         39                   
sserv9    7-9        Motherboard Temperature 1 42                   
sserv9    7-11       Motherboard Temperature 2 41                   
sserv9    7-12       CPU 2 Temperature         41                   

The following command example displays warnings and information for a sensor named 7-10 in a SpinServer named sserv10.

spinserver::> sensors temp show -ssid sserv10 -key 7-10
Host Name               sserv10                                 
Sensor ID               7-10                                    
Sensor Description      CPU 1 Temperature                       
Temperature (Celsius)   38                                      

sensors ups show

Name

sensors ups show -- Use the sensors ups show command to view operational information for a SpinServer's uninterruptible power supply (UPS).

Synopsis

CLI:

sensors ups show [-ssid spinserver]

GUI: Navigate to the Sensors → UPS node. To display information about a specific UPS, select it from the table and run the Show command from the drop-down menu of the action pane.

Description

The sensors ups show command displays information about the operational performance of the UPS attached to a SpinServer. The following information is displayed:

Options

[-ssid spinserver]

This is the ID given to the SpinServer.

Example

The following command example displays information about the operational performance of the UPSs in a SpinServer cluster.

spinserver::> sensors ups show 
SpinServer ID Utility   Power Off  Last Battery   Minutes  
                Line    Threshold   Change Date     Left   
              Voltage 
                                                           
ss1           117      15          05/22/01      73        
ss2           117      15          05/22/01      104       